Product Details:

Place of Origin: Beijing, China
Certification: CE, SGS
Model Number: Covid-19 test kits

Payment & Shipping Terms:

Minimum Order Quantity: 10 pcs
Price: USD1.8-3.5/PC
Packaging Details: BOX
Delivery Time: 3-7 DAYS
Payment Terms: L/C, T/T
Supply Ability: 1000 Pieces per Day
Get Best Price Contact Now

Detail Information

Name: COVID-19 Antigen Rapid Test Kit Material: Plastic, Other
Use: Covid-19 Testing Shelf Life: 2 Years
Specification: 25 Tests/kit MOQ: 10 Pcs
High Light:

Disposable Saliva Test Kit

,

SGS Saliva Test Kit

,

Disposable Covid-19 Antigen Test Kit

Product Description

Disposable Saliva Test Kit , SGS Covid-19 Antigen Test Kit

Saliva test kit Covid-19 Antigen Rapid Test Kit disposable White-blue

 

Coronaviruses are enveloped RNA viruses that are distributed broadly among humans, other mammals, and birds and that cause respiratory, enteric, hepatic, and neurologic diseases.

 

Seven coronavirus species are known to cause human disease. Four viruses - 229E, OC43, NL63, and HKU1 - are prevalent and typically cause common cold symptoms in immunocompetent individuals.

The three other strains - severe acute respiratory syndrome coronavirus (SARS-CoV), Middle East respiratory syndrome coronavirus (MERS-CoV) and 2019 Novel Coronavirus (COVID-19) - are zoonotic in origin and have been linked to sometimes fatal illness.

 

The COVID-19 Antigen Rapid Test Kit can detect pathogen antigens directly from oral saliva specimen.

 

SPECIMEN COLLECTION AND HANDLING
1. Gargle with clean water before sampling
2. Unscrew the lid of the Extraction Tube, insert the saliva specimen collection funnel and screw it tightly.
3. Cough up secretions deep in the throat, accumulated in the oral cavity.
4. Use a saliva specimen collection funnel to collect fresh secretions in the oral cavity, reach the oral secretion scale mark.
5. Unscrew the funnel to allow the secretions to slip into the extraction buffer, tighten the funnel immediately and shake the collection tube.
6. Rotate to remove the funnel, place the white tip into the collection tube.

 

STORAGE AND STABILITY

The kit can be stored at room temperature or refrigerated (2-30°C). The test device is stable through the expiration date printed on the sealed pouch. The test device must remain in the sealed pouch until use.

DO NOT FREEZE. Do not use beyond the expiration date.

 

WARNINGS AND PRECAUTIONS

    1. For professional In Vitro diagnostic use only. Do not use after expiration date.

2. This package insert must be read completely before performing the test. Failure to follow the insert gives inaccurate test results.

3. Do not use it if the pouch is damaged or broken.

4. Test is for single use only. Do not re-use under any circumstances.

5. Handle all specimens as if they contain infectious agents. Observe established precautions against microbiological hazards throughout testing and follow the standard procedures for proper disposal of specimens.

6. Wear protective clothing such as laboratory coats, disposable gloves and eye protection when specimens are assayed.

7. Humidity and temperature can adversely affect results.

8. Do not perform the test in a room with strong air flow, ie. electric fan or strong air- conditioning.

9. Test is only for oral saliva specimens If test other specimens such as nasal, throat or nasopharyngeal swab specimens or serumplasmaurine specimens, the results are only for research.

10. Sample collection and handling procedures require specific training and guidance.

11. Do not pour sample from the Extraction Tube into the Test Cassette sample well. Use the provided dispensing tip of Extraction Tubes when adding the sample to the Test Cassette.

 

TEST PROCEDURE

Allow test cassette, specimen, and/or controls to equilibrate to room temperature (15-30°C) prior to testing.

    1. Cover the extraction tube with its dispensing tip.

2. Remove the test cassette from the sealed foil pouch and use it as soon as possible. Best results will be obtained if the assay is performed within one hour.

3. Place the test device on a clean and level surface.

4. Squeeze the collection tube to add 2 drops of extracted sample into the specimen well(S) of the test device.

5. Read the results at 15 minutes. Do not interpret any result after 20 minutes.

 

FAQ

    1. How can I get some samples?

        We are honored to offer you samples.
    2. Can you produce the products according to my own drawings?
        Yes, we can produce the products according to your drawings that will be most satisfy you.

 

Disposable Saliva Test Kit , SGS Covid-19 Antigen Test Kit 0Disposable Saliva Test Kit , SGS Covid-19 Antigen Test Kit 1Disposable Saliva Test Kit , SGS Covid-19 Antigen Test Kit 2

 

Want to Know more details about this product
I am interested in Disposable Saliva Test Kit , SGS Covid-19 Antigen Test Kit could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.